{"id":57,"date":"2014-06-02T12:01:50","date_gmt":"2014-06-02T12:01:50","guid":{"rendered":"http:\/\/www.icmm.csic.es\/nmr\/?page_id=57"},"modified":"2014-06-02T12:01:50","modified_gmt":"2014-06-02T12:01:50","slug":"hardware","status":"publish","type":"page","link":"https:\/\/wp.icmm.csic.es\/nmr\/service\/hardware\/","title":{"rendered":"Equipment"},"content":{"rendered":"<ul>\n<li>BRUKER NMR Spectometer: AVANCE 400 Console, 9.4 Tesla magnet (400MHz)<\/li>\n<\/ul>\n<ul>\n<li>7 MAS probes to cover different spinning speeds and a wide range of nuclei:<\/li>\n<\/ul>\n<table border=\"1\" width=\"573\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td style=\"text-align: center\" valign=\"middle\" bgcolor=\"#DBE1D5\" width=\"64\"><strong> Rotor <\/strong><\/td>\n<td style=\"text-align: center\" valign=\"middle\" bgcolor=\"#DBE1D5\" width=\"85\"><strong>MAS spinning speed<\/strong><\/td>\n<td style=\"text-align: center\" valign=\"middle\" bgcolor=\"#DBE1D5\" width=\"283\"><strong>Observed frequencies<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center\" valign=\"top\" width=\"64\">2.5 mm<\/td>\n<td style=\"text-align: center\" valign=\"top\" width=\"85\">20 kHz<\/td>\n<td style=\"text-align: center\" valign=\"top\" width=\"283\">31P-15N (162-40.5 MHz)\/1H-19F (400-376.5 MHz)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center\" valign=\"top\" width=\"64\">4 mm<\/td>\n<td style=\"text-align: center\" valign=\"top\" width=\"85\">10 kHz<\/td>\n<td style=\"text-align: center\" valign=\"top\" width=\"283\">31P-15N (162-40.5 MHz)\/1H (400MHz)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center\" valign=\"top\" width=\"64\">4 mm<\/td>\n<td style=\"text-align: center\" valign=\"top\" width=\"85\">10 kHz<\/td>\n<td style=\"text-align: center\" valign=\"top\" width=\"283\">31P-13C (162-100 MHz)\/19F (376.5 MHz)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center\" valign=\"top\" width=\"64\">7 mm<\/td>\n<td style=\"text-align: center\" valign=\"top\" width=\"85\">5 kHz<\/td>\n<td style=\"text-align: center\" valign=\"top\" width=\"283\">31P-13C (162-100 MHz)\/1H (400MHz)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center\" valign=\"top\" width=\"64\">7 mm<\/td>\n<td style=\"text-align: center\" valign=\"top\" width=\"85\">5 kHz<\/td>\n<td style=\"text-align: center\" valign=\"top\" width=\"283\">13C-2H (100-61 MHz)\/1H (400MHz)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center\" valign=\"top\" width=\"64\">7 mm<\/td>\n<td style=\"text-align: center\" valign=\"top\" width=\"85\">5 kHz<\/td>\n<td style=\"text-align: center\" valign=\"top\" width=\"283\">29Si-109Ag (79-18 MHz)\/1H (400 MHz)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<ul>\n<li>Static probe for pulse field gradient experiments (4 inserts available):<\/li>\n<\/ul>\n<table border=\"1\" width=\"500\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td style=\"text-align: center\" valign=\"top\" bgcolor=\"#DBE1D5\" width=\"144\"><strong> Tube diameter <\/strong><\/td>\n<td style=\"text-align: center\" valign=\"top\" bgcolor=\"#DBE1D5\" width=\"144\"><strong>Observed nucleus<\/strong><\/td>\n<td style=\"text-align: center\" valign=\"top\" bgcolor=\"#DBE1D5\" width=\"144\">T<strong>emperature<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center\" valign=\"top\" width=\"144\">5 mm<\/td>\n<td style=\"text-align: center\" valign=\"top\" width=\"144\">7Li<\/td>\n<td style=\"text-align: center\" valign=\"top\" width=\"144\">300-480 K<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center\" valign=\"top\" width=\"144\">5 mm<\/td>\n<td style=\"text-align: center\" valign=\"top\" width=\"144\">1H<\/td>\n<td style=\"text-align: center\" valign=\"top\" width=\"144\">Room temperature<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center\" valign=\"top\" width=\"144\">5 mm<\/td>\n<td style=\"text-align: center\" valign=\"top\" width=\"144\">23Na<\/td>\n<td style=\"text-align: center\" valign=\"top\" width=\"144\">173-473 K<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center\" valign=\"top\" width=\"144\">8 mm<\/td>\n<td style=\"text-align: center\" valign=\"top\" width=\"144\">7Li<\/td>\n<td style=\"text-align: center\" valign=\"top\" width=\"144\">Room temperature<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<ul>\n<li>Static probe for the study of powder and single-crystal for nuclei 31P-109Ag (162-18 MHz).<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>BRUKER NMR Spectometer: AVANCE 400 Console, 9.4 Tesla magnet (400MHz) 7 MAS probes to cover different spinning speeds and a wide range of nuclei: Rotor MAS spinning speed Observed frequencies 2.5 mm 20 kHz 31P-15N (162-40.5 MHz)\/1H-19F (400-376.5 MHz) 4<\/p>\n","protected":false},"author":70,"featured_media":0,"parent":43,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"ngg_post_thumbnail":0,"footnotes":""},"class_list":["post-57","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/wp.icmm.csic.es\/nmr\/wp-json\/wp\/v2\/pages\/57","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wp.icmm.csic.es\/nmr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/wp.icmm.csic.es\/nmr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/wp.icmm.csic.es\/nmr\/wp-json\/wp\/v2\/users\/70"}],"replies":[{"embeddable":true,"href":"https:\/\/wp.icmm.csic.es\/nmr\/wp-json\/wp\/v2\/comments?post=57"}],"version-history":[{"count":0,"href":"https:\/\/wp.icmm.csic.es\/nmr\/wp-json\/wp\/v2\/pages\/57\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/wp.icmm.csic.es\/nmr\/wp-json\/wp\/v2\/pages\/43"}],"wp:attachment":[{"href":"https:\/\/wp.icmm.csic.es\/nmr\/wp-json\/wp\/v2\/media?parent=57"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}